Publication scientifique

AccueilMicrostructured thin-film electrode technology enables proof of concept of scalable, soft auditory...

Microstructured thin-film electrode technology enables proof of concept of scalable, soft auditory brainstem implants

Engineered conformability in auditory brainstem implant electrode arrays improves the electrode-brainstem interface in mice and in human cadavers. , Beneficial bending Some people with deafness receive auditory brainstem implants (ABIs), neurotechnology that directly stimulates the cochlear nucleus (CN). Unfortunately, auditory outcomes after implantation are limited, possibly due to mismatch between the stiffness of the implant and the CN. Vachicouras et al . developed ABIs that conform to the curvature of the CN. The soft arrays could be easily handled during surgery and functioned over 1 month when implanted in mice. A scaled-up version of the conformable ABIs inserted in human cadavers showed good electromechanical and electrochemical stability and a potentially larger dynamic range compared to the clinical ABIs. These proof-of-concept results support further testing in models of deafness. , Auditory brainstem implants (ABIs) provide sound awareness to deaf individuals who are not candidates for the cochlear implant. The ABI electrode array rests on the surface of the cochlear nucleus (CN) in the brainstem and delivers multichannel electrical stimulation. The complex anatomy and physiology of the CN, together with poor spatial selectivity of electrical stimulation and inherent stiffness of contemporary multichannel arrays, leads to only modest auditory outcomes among ABI users. Here, we hypothesized that a soft ABI could enhance biomechanical compatibility with the curved CN surface. We developed implantable ABIs that are compatible with surgical handling, conform to the curvature of the CN after placement, and deliver efficient electrical stimulation. The soft ABI array design relies on precise microstructuring of plastic-metal-plastic multilayers to enable mechanical compliance, patterning, and electrical function. We fabricated soft ABIs to the scale of mouse and human CN and validated them in vitro. Experiments in mice demonstrated that these implants reliably evoked auditory neural activity over 1 month in vivo. Evaluation in human cadaveric models confirmed compatibility after insertion using an endoscopic-assisted craniotomy surgery, ease of array positioning, and robustness and reliability of the soft electrodes. This neurotechnology offers an opportunity to treat deafness in patients who are not candidates for the cochlear implant, and the design and manufacturing principles are broadly applicable to implantable soft bioelectronics throughout the central and peripheral nervous system.

Autres publications de la plateforme

The e-Flower: A hydrogel-actuated 3D MEA for brain spheroid electrophysiology

Martinelli, Eleonora; Akouissi, Outman; Liebi, Luca; Furfaro, Ivan; Maulà, Desirée; Savoia, Nathan; Remy, Antoine; Nikles, Laetitia; Roux, Adrien; Stoppini, Luc; Lacour, Stéphanie P.
Science Advances
Plateforme de Micro-Systèmes Neuronaux (NMP)

Wireless, battery-free, and real-time monitoring of water permeation across thin-film encapsulation

Mariello, Massimo; Rosenthal, James Daniel; Cecchetti, Francesco; Gao, Mingxiang; Skrivervik, Anja K.; Leterrier, Yves; Lacour, Stéphanie P.
Nature Communications

Optical Monitoring of Water Side Permeation in Thin Film Encapsulation

Wu, Kangling; Mariello, Massimo; Leterrier, Yves; Lacour, Stéphanie P.
Advanced Materials

A low-profile electromechanical packaging system for soft-to-flexible bioelectronic interfaces

Fallegger, Florian; Trouillet, Alix; Coen, Florent-Valéry; Schiavone, Giuseppe; Lacour, Stéphanie P.
APL Bioengineering

Deployment of an electrocorticography system with a soft robotic actuator

Song, Sukho; Fallegger, Florian; Trouillet, Alix; Kim, Kyungjin; Lacour, Stéphanie P.
Science Robotics

Subdural Soft Electrocorticography (ECoG) Array Implantation and Long-Term Cortical Recording in...

Fallegger, Florian; Trouillet, Alix; Lacour, Stéphanie P.
Journal of Visualized Experiments

Journal de publication

Science Translational Medicine

Auteurs:

Vachicouras, Nicolas; Tarabichi, Osama; Kanumuri, Vivek V.; Tringides, Christina M.; Macron, Jennifer; Fallegger, Florian; Thenaisie, Yohann; Epprecht, Lorenz; McInturff, Stephen; Qureshi, Ahad A.; Paggi, Valentina; Kuklinski, Martin W.; Brown, M. Christian; Lee, Daniel J.; Lacour, Stéphanie P.

Date de publication:

Plateforme:

Études récentes de la plateforme

Neuro-ingénierieNeurosciences cliniques et translationnelles

Restaurer le mouvement après une paralysie

Stimulation électrique de la moëlle épinière Un réseau d’électrodes implantables, connecté à un stimulateur implanté, délivre des impulsions électriques aux différents nerfs spinaux. Chaque...
Plateforme d’Imagerie par Résonance Magnétique (IRM)Plateforme de Micro-Systèmes Neuronaux (NMP)Plateforme de Neurosciences Précliniques (PNP)Plateforme M/EEG & Neuromod (MEG)

Suivi de la dopamine dans la maladie de Parkinson

Détection de la dopamine grâce à des biosenseurs à base d’ADN Une approche innovante utilise des brins d’ADN artificiellement conçus, appelés aptamères, qui capturent...

Suivre la trace des biomarqueurs sanguins de la maladie d’Alzheimer

Réinventer le diagnostic de la maladie d'Alzheimer La maladie d’Alzheimer se développe des décennies avant l’apparition des symptômes. Des recherches récentes suggèrent que le risque...